A worker sustained serious head injury when an 80 foot wooden truss fractured during building construction and struck him. A reconstruction of the rigging configuration combined with a dynamic finite element stress analysis of the truss stresses generated during construction showed that the failure occurred from improper rigging when the truss was being lifted into position and not as a result of a defect.